Search results

  1. L

    Ecosolvent DX4 head, Roland SP300 strange banding

    This is not inkjet related, and seems very specific, but maybe someone has encountered it. I always thought that the banding is due to cloged nozzles of magenta Here the head printest for cyan is ok: But I noticed that banding seems to be caused by the cyan printing beyond image here: You...
  2. L

    What is wrong with my Konica Minolta 1490MF

    When I print printer reports, generated SUDOKU, everything seems to be very contrast and crisp. But when I try to copy, there is horizontal banding, and vertical Printed: https://drive.google.com/file/d/1XcqpojZqWe5ZX39S1EGg6AQJ8QXtdw92Iw/view?usp=sharing Copied...
  3. L

    Does the Canon W6200 head has filters in it?

    Hi, I have got a printer W6200 which has been unused for a long time. Tubes were semifilled with ink, so there were many air cavities.Black, Magenta color nozzles clogged completelly, only cyan printing correctly. I have flushed the tubes with solution many times however some ink stains...
  4. L

    inkjet feed tube cleaning

    Hi, got Canon W6200 for free, but it stayed for half of a year unused with empty cardriges, the feed tubes with air bubles and seems there are dried spots of ink. Do you have any suggestions how to flush/clean the feed tubes.