Search results

  1. E

    [QUIZ] Can You Finish the Print Lingo? 🧠

    You can find hundreds of web references telling you: Or something similar. It isn't specific to inkjet printers. The color mixing bleed seems to usually be called 'ink bleed'. As for the OP I assume you are trying to drum up a bit more activity on the forum. An admirable idea which doesn't...
  2. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    I had a quick look and saw 60 bytes sent for each button press. I expect those 60 bytes mostly contain 31 spectral measurements. I would look at spectral measurement values in ColorQC 2 at try to find that data in those 60 bytes. That said I don't think ColorQC is too painful to use. Trying to...
  3. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    That would be much more complicated. I envisage a jig like this The CR30 is a loose fit in the jig main part. The collar around the CR30 is fixed. The jig lifts the CR30 by the collar, moves it to the next patch, lowers it to the target then drops some more to briefly press the CR30 button...
  4. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    I see ConradH asking about CR30 communications on DPReview. I don't participate there. FYI the CR30 USB interface is just a serial port implemented with a CH340 USB -> serial chip. While connected you will see the CR30 in windows device manager under serial ports as "USB-SERIAL CH340". There...
  5. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    A small, but, useful update to the target generators, ti3 generation script, and instructions.
  6. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    And a few batch files named paper_sizexpatch_countxpatch_size to generate various targets on one or two sheets.
  7. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    Yesterday I created an A5 target with 384 randomized 8mm patches. I printed it on half an A4 sheet of Epson Premium Glossy paper on an ET-7750. I measured the target this morning which took nearly 20 minutes. I am sure with practice and a bit more care that could be reduced. Aligning the rule...
  8. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    I am using 8mm patches and the rule I designed so you only need to see a couple of patch 'joints' to align the rule. I have never had any ti3 files from chartread to look at. It appears the colprof needs the input RGB values (from the ti2 file) followed by measured values on each data line. I...
  9. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    Today for the first time I printed and measured a target. The target was randomized and I couldn't generate a profile. I think the build_profile script is not doing the right thing. The patches are randomized on the sheet and the ti2 file has a SAMPLE_LOC to tell you where they are on the...
  10. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    Something is messed up. I don't know what your .colors file is. I generated an A5 10mm patch target from your 228 ti1 file with this printtarg.exe -r -v -i 22 -p 148.492x210 -a1.25 -T360 -m3 "my 228-target" and got this Which doesn't look like your photos. The 4th patch (A4) in the ti1/ti2...
  11. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    I have not tried generating a profile yet. I have an i1studio so I don't really need to. I bought the CR30 because it is cheap and interesting and could be convenient for spot reading. I was/am waiting for the scripts you guys are producing to be finished and stable then I will probably have a...
  12. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    The target is straight out of printtarg. No need to edit. All you need is something that can print without color management and to scale obeying the 360DPI file resolution. I use Qimage. I played around some more with printtarg and -i22 is the best instrument setting for square patches. If you...
  13. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    This targen -v -d2 -g 16 -f 486 test printtarg -r -v -i 22 -p A4 -a 1.2506 -T914.4 test produces 486 x 10mm square patches on an A4 sheet: The instrument type parameter seems to control the shape of the patches and peripheral annotations. The -a parameter scales the patch size. I didn't look...
  14. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    Here is a collar and 300mm rule for 10mm square patches. Rule and collar on your 247 patch target scaled by forced printing at 518 dpi. Align the rule to the edge of the patches with notches central. Press the button and slide to the next notch. I can't see how that isn't faster and less...
  15. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    I noticed the calibration cap has a serial number matching that which the device reports to the application. Our white calibration values differing shows the device has has a factory calibration for itself and associated calibration cap.
  16. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    With a collar like I suggested and a patch pitch notched rule you would only have to align the rule for each column the CR30 would just be slid along to the next notch. My calibration patch reads 89.44 -0.71 0.12 (D65 source) is yours the same? The documentation is pathetic. I just noticed...
  17. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    Thanks both for the work you have done on this device. I had a CR30 delivered today. I think with care you could go smaller than 15mm square patches. The hole in the bottom of the CR30 is only 5mm. If I do end up using the CR30 for printer profiles I think I would print a collar for it...
  18. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    The CR10/20/30 are at the bottom of the page I linked. I assume they are the manufacturer or at least closer to them than aliexpress and so a good source for documentation and software. The link to windows software for the CR series seems broken. I guess it is common to some of the other...
  19. E

    Possibility to convert csv-file with only L*A*B* values into a ArgyllCMS ti3 file

    The file says NUMBER_OF_FIELDS = 7 while the DATA_FORMAT statement has 8 fields. 228 * 7/8 = 200 Looks like it just reads data elements according to the data format ignoring new lines. Are you sure argyll needs RGB and XYZ values anyway? If you can generate them from Lab then argyll could as...
  20. E

    Calibrite Profiler 3.0

    I'm sure the posts here will contribute in a small way to information AI bots trawl from the internet and regurgitate so eloquently. That doesn't stop me hiding (under a VPN for starters). The less google (the biggest and worst collector and correlator of personal information) know about me...
Top